Product Description RKI’s Model OX-600 is an indoor, standalone monitor that detects Oxygen (O2) with a range of 0-25.0 % volume with 0.1% increments. It’s sleek, low-profile design is equipped with a unique tri-color display, which changes color as oxygen levels reach each alarm level. The OX-600 has 2 preset alarms, and comes ready to operate with a simple wall mount bracket and 10 foot power cord. It is capable of operating with three different power options; 115 VAC, 24 VDC or alkaline batteries. If Oxygen is deficient, the user is notified by an audible alarm tone and the multicolored LED digital display. The OX-600 uses a fast responding low-cost plug-in style galvanic cell sensor. This long life sensor is field-replaceable with no special tools required. The sensor can also be remotely mounted with an optional (Sold Separately) remote sensor cable. Perfect for Oxygen Deficiency Monitoring in Labs and Hospitals With Nitrogen Tanks Hospitals use and store large quantities of industrial and medical gas cylinders and containers; one common container is for liquid nitrogen. Liquid nitrogen provides temperatures as low as -196°C and it can be used for cryobiology and cryotherapy. The low temperature is used in cryo-conservation for the long-term preservation of blood, blood components, other cells, body fluids or tissue samples. The presence of nitrogen cylinders and containers requires a focus on safety. Liquid Nitrogen rapidly vaporizes to gas at about 700 times the liquid volume. By displacing air the gas may kill by asphyxiation. When the oxygen concentration in air is sufficiently low, a person can become unconscious without any warning symptoms. RKI’s Model OX-600, stand alone oxygen monitor units, can monitor individual rooms that store nitrogen containers. An optional remote mount sensor and cable can be equipped which allows the unit to be mounted on the outside of the room, in the hallway, while the extender cable allows the sensor to be located in the area with the nitrogen containers. This allows a person to recognize the condition of a room storing nitrogen prior to entering. Being aware of oxygen deficiency in the presence of compressed nitrogen cylinders or liquid nitrogen containers can save lives. The OX-600 is an indoor, standalone monitor that detects Oxygen (O2) with a range of 0-25.0 % volume with 0.1% increments. Its sleek, low profile design is equipped with a unique tri-color display, which changes color as oxygen levels reach each alarm level. The OX-600 has 2 preset alarms, and comes ready to operate with a simple wall mount bracket and 10 foot power cord. It is capable of operating with three different power options: 115 VAC, 24 VDC or alkaline batteries (in Canada, only the 24 VDC and alkaline versions are available currently). If Oxygen is present, the user is notified by an audible alarm tone and the multicolored LED digital display. The OX-600 uses a fast responding low-cost plug-in style galvanic cell sensor. This long life sensor is field- replaceable with no special tools required. The sensor can also be remotely mounted when instrument is supplied with optional sensor cable. SPECIFICATIONS Two preset alarms (L-LL), alarm 1 = 19.5% vol, alarm 2 = 23.5% vol (other settings available) 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer Gas Detected Oxygen (O2) Detection Range: 0 - 25 vol% Display Resolution: 0.1 vol% Sampling Method Diffusion Indication Accuracy* Within ±0.7 vol% Response Time* 90% Response within 30 seconds Alarm Delay Time* Within 5 seconds, after detecting 10 ~ 11 vol% gas at Oxygen deficiency alarm (18 vol% alarm). Alarm Accuracy* Within ±1 vol% of preset alarms Display of Alarm 1st gas alarm: gas concentration reading blinks or orange light, flashing AL1 light or orange light, buzzer 2nd gas alarm: gas concentration reading blinks or red light, flashing AL2 light or red light, buzzer Alarm Method Latching or Non-latching Alarm Contact Dry contact, Form A or Form B, Form A standard Factory Setting, normally open (closed in ALARM) Display Digital LCD (3 digits, 7 segments / Green, Orange, Red) (For Alkaline battery version, the back light will be OFF during normal operation) Trouble Alarm / Self-Diagnosis System trouble / sensor connection trouble Display of Trouble Alarm Buzzer / content indication (flashing of red error message) Trouble Alarm Method Non-latching or Latching Contact Capacity 125VAC, 1A or 30VDC, 1A (Resistive load) Output Signal 4 ~ 20mA (Non-isolated, Resistive load under 300Ω) or 0DC-1V (Non-isolated) *only for 0DC-1V Alkaline battery specification Extender Cable Extender cable with remote box (3m, 5m, 10m or 20m lengths available) Power Sources 120VAC±10%, 50/60Hz, 24VDC±10%, or AA alkaline battery (2 each) Power Consumption AC specification: MAX 3.5VA, DC specification: MAX 2W Continuous Operation (for Alkaline Battery version) 1 year (no alarm, no indication) Initial Clear About 25 seconds Operating Temperature 0 ~ 104°F (no sudden change) Operating Humidity Below 90%RH (non-condensing) Mounting Equipment Wall mounting, sensor integrate type or remote type Dimension Body: approx. 3.15”(W) x 4.72”(H) x 1.2”(D) (80(W) x 120(H) x 35.5(D)mm) Remote sensor: approx. 1.57”(W) x 3.78”(H) x 1.2”(D) 40(W) x 96(H) x 35.5(D)mm (exclude the protrusion) Weight AC specification: approx. 7.05 oz (200g), DC specification: approx. 6.34 oz (180g), Alkaline battery specification: approx. 8.11 oz (230g) Remote sensor: approx. 1.94 oz (55g) (exclude the cable) Warranty One year materials and workmanship
Best Seller RKI OX-600 O2 Oxygen Gas Monitor, 0-25% Range, 115 VAC Power Cord | Mfg# 72-1006 MFG# RKI-72-1006 $800.00 $740.00 Add To Cart
RKI Instruments OS-BM1D Replacement O2 Oxygen Gas Sensor for OX-600 Monitor, 0-25% Range MFG# RKI-OS-BM1D $175.00 $150.00 Add To Cart
RKI OX-600 O2 Oxygen Gas Monitor, With 5 Meter Remote O2 Sensor, 0-25% Range, 115 VAC | Mfg# 72-1006-05 MFG# RKI-72-1006-05 $1,025.00 $973.75 Add To Cart
RKI OX-600 O2 Oxygen Gas Monitor, With 10 Meter Remote O2 Sensor, 0-25% Range, 115 VAC | Mfg# 72-1006-10 MFG# RKI-72-1006-10 $1,160.00 $1,102.00 Add To Cart