RKI Instruments GX-Force Confined Space Kit features the RKI GX-Force Monitor, a full cylinder of RKI calibration gas, a demand flow regulator, tubing, and a padded case.
Applications: Personal monitoring, Confined spaces, Refineries/petrochemical, Utilities, Oil and Gas, Water/wastewater, Fire services, Construction
Kit Includes:
- RKI GX-Force 4 sensors, LEL / O2 / H2S / CO gas monitor with Li-Ion battery pack
- One aluminum 34L cylinder of cal gas (H2S/CO/O2/CH4)
- Demand flow regulator
- Tubing
- Padded Case
| Detection Target Gas |
Combustible gas (CH4) |
Oxygen (O2) |
Carbon monoxide (CO) |
Hydrogen sulfide (H2S) |
| Detection Principle |
Catalytic combustion |
Electrochemical type |
Electrochemical type |
Electrochemical type |
| Detection Range |
0 – 100 % LEL |
0.0 – 40.0 vol % |
0 – 2,000 ppm |
0.0 – 200.0 ppm |
| Resolution |
1 % LEL |
0.1 vol % |
1 ppm |
0.1 ppm |
| Alarm Setpoints |
1st alarm: 10 % LEL 2nd alarm: 25 % LEL 3rd alarm: 50 % LEL OVER alarm: 100 % LEL |
L alarm: 19.5 vol % LL alarm: 18.0 vol % H alarm: 23.5 vol % OVER alarm: 40.0 vol % |
1st alarm: 25 ppm 2nd alarm: 50 ppm 3rd alarm: 1200 ppm TWA alarm: 25 ppm STEL alarm: 200 ppm OVER alarm: 2,000 ppm |
1st alarm: 5.0 ppm 2nd alarm: 30.0 ppm 3rd alarm: 100.0 ppm TWA alarm: 1.0 ppm STEL alarm: 5.0 ppm OVER alarm: 200.0 ppm |
| Response Time (T90) |
Within 30 seconds |
Within 20 seconds |
Within 30 seconds |